Probable Cause:

  • Drive’s internal boost circuit is reporting >400V DC on the bus.

Corrective Action:

  • Verify line voltage isn’t spiking.
  • Check the internal AC wiring of the treadmill.
  • Verify correct voltage controller is used with regard to power at the outlet.
  • Replace the Drive Controller if the error continues.